Blue Line - Control units  | Jürgen Schlösser Armaturen GmbH

Blue Line - Control units

Blue Line

Product­information:

The Blue Line controller task is to control a floor central heating system.

Product­variations:

Article no. Type Zones Voltage Pumps / boiler output Heating / cooling EAN
9408 9110 605 Standard 6 230 V / 24 V No / No Yes / No 42604 7795 0406
9408 9110 606 Standard 10 230 V / 24 V No / No Yes / No 42604 7795 0413
9408 9110 608 Standard plus 6 230 V Yes / No Yes / Yes  42604 7795 0420
9408 9118 608 Standard plus 6 24 V Yes / No Yes / Yes  42604 7795 1854
9408 9110 609 Standard plus 10 230 V Yes / No Yes / Yes  42604 7795 0581
9408 9118 609 Standard plus 10 24 V Yes / No Yes / Yes  42604 7795 1861
9408 9110 610 Comfort 6 230 V Yes / Yes Yes / Yes  42604 7795 1090
9408 9118 610 Comfort 6 24 V Yes / Yes Yes / Yes  42604 7795 1878
9408 9110 611 Comfort 10 230 V Yes / Yes Yes / Yes  42604 7795 1106
9408 9118 611 Comfort 10 24 V Yes / Yes Yes / Yes  42604 7795 1885
Name Description
Operating voltage: 230V AC
Actuator: 6 heating zones: max. 15 10
heating zones: max. 18
Rated load of all drives: max. 24 W
Pump / boiler control
- Activation delay:
- Stopping time fixed / adjustable:

2 min
2 min
Pump protection function: 14 days for 1 minute
  Standard Standard plus Comfort
Operating voltage 230 V / 24 V 230 V 24 V 230 V 24 V 230 V 24 V 230 V 24 V
Zones 6 10 6 10 6 10
Type Wired
Protective conductor
Intermediate connector
    x   x   x   x  
Networked by terminal for
Pump / boiler circuit
    x   x   x   x  
Networked by terminal
for dew point sensor
      x   x   x   x
Expanded pump /
boiler control
Stopping time configurable
            x x x x
Simple
Pump control
    x x x x        
Signal input for temperature
limiter or dew point sensor
    x x x x x x x x
Reduction duct - Connection
for an external system clock
x x x x x x x x x x
Changeover connection signal
for heating / cooling
    x x x x x x x x
Timer module - housing -
cover with integrated
system clock
            Optional
Control direction normally closed (NC) /
normally open (NO)
NC/NO NC (without pump controller as NO) Selectable
Function signaling
by LEDs
            x
Power supply 24 V: System transformer with Euro connection / external voltage source
230 V: Euro plug / external voltage source
Max. power consumption
(without pump / boiler
device)
24 V : max. 36 VA
230 V : max. 50 VA
Max. number of
thermostats
6 10 6 10 6 10
Max. number of
connection terminals
for actuators
15 21 15 21 15 21
Max. rated load
of all drives
24 V : 24 W
230 V : --
Temperature limiter
or dew point sensor
Potential-free normally closed, switchable, 24 V / 230 V, 8 A
Weight 410 g 424 g 428 g 448 g 442 g 466 g
Dimensions (W x H x D) 90 x 326 x 52 mm

Looking for other downloads?

You'll find them in our Download-Center.

read more

Close
Or ask us directly: +49 2762 / 979277